Will this switch power these cameras?
Enter the camera mix — fixed domes, PTZs, heated or multi-sensor units — and either name a switch or let the registry rank every model that matches your filters. The planner adds up the PoE demand, holds it against the switch's rated PoE budget with an operating reserve set by the headroom, checks the port count, checks the highest powered-device ceiling against the per-port maximum, and checks that the ports negotiate every camera class's IEEE standard. It returns FIT, FIT WITH RISKS, NEEDS VALIDATION or NO FIT, with how many cameras of each class the switch can hold and the model that would fit instead.
Method v2.2.0 · data verified 2026-09-26 · registries: poe-switches · methodology
01 · Describe the camera mix
Advanced
03 · How this works
Four checks on one demand figure
The node's PoE demand is each camera group's count times the typical draw for its class. Ports holds the camera count against the switch's PoE port count — filling every port exactly is a NEAR LIMIT, not a pass, because there is no spare. Per-port ceiling holds the highest powered-device ceiling in the mix against the switch's per-port maximum. Budget holds the demand against the switch's published (rated) PoE budget; the headroom sets an operating reserve of rated × headroom — demand above the reserve is a NEAR LIMIT, demand above the rated budget is a FAIL. Standard checks that the switch's ports negotiate every camera class's IEEE standard, treating PoE as backward compatible: a higher-tier port powers a lower-tier camera, but an 802.3bt Type 3 camera on an 802.3at-only switch is a NO FIT.
Sourced switches, labelled estimates
Every switch figure — port counts, budget, per-port ceiling, standards, uplink, industrial rating, operating range — comes from the vendor's own page, quoted and linked. The per-camera draws (7 W fixed, 22.5 W PTZ, 50 W heated) and the 0.8 budget headroom are class E engineering defaults and are labelled as such in every result. A shortfall that rests only on a class E figure — a typical draw, a camera class's assumed PoE standard — is NEEDS VALIDATION, never NO FIT; stating the IEEE class or the per-camera watts makes it a FAIL. The IEEE powered-device maxima (12.95 / 25.5 / 51 / 71.3 W) are class A figures from the vendor standards table, cited in every result; with a stated poe_class the per-port check stamps elimination_authority: bounded_model on that ceiling. A figure the vendor page does not publish is UNKNOWN, which is why some switches come back NEEDS VALIDATION.
Full rules, the class E defaults and what invalidates a result: methodology. Raw dataset: datasets/poe-switches.json. Related: Power Budget sizes the whole node's supply; Network Bandwidth sizes the uplink the same switch carries.